983 resultados para Insulin Infusion Systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Improved glycemic control is the only treatment that has been shown to be effective for diabetic peripheral neuropathy in patients with type 1 diabetes (1). Continuous subcutaneous insulin infusion (CSII) is superior to multiple daily insulin injection (MDI) for reducing HbA1c and hypoglycemic events (2). Here, we have compared the benefits of CSII compared withMDI for neuropathy over 24months....

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Sensor-augmented pump therapy (SAPT) integrates real-time continuous glucose monitoring (RT-CGM) with continuous subcutaneous insulin infusion (CSII) and offers an alternative to multiple daily injections (MDI). Previous studies provide evidence that SAPT may improve clinical outcomes among people with type 1 diabetes. Sensor-Augmented Pump Therapy for A1c Reduction (STAR) 3 is a multicenter randomized controlled trial comparing the efficacy of SAPT to that of MDI in subjects with type 1 diabetes. METHODS: Subjects were randomized to either continue with MDI or transition to SAPT for 1 year. Subjects in the MDI cohort were allowed to transition to SAPT for 6 months after completion of the study. SAPT subjects who completed the study were also allowed to continue for 6 months. The primary end point was the difference between treatment groups in change in hemoglobin A1c (HbA1c) percentage from baseline to 1 year of treatment. Secondary end points included percentage of subjects with HbA1c < or =7% and without severe hypoglycemia, as well as area under the curve of time spent in normal glycemic ranges. Tertiary end points include percentage of subjects with HbA1c < or =7%, key safety end points, user satisfaction, and responses on standardized assessments. RESULTS: A total of 495 subjects were enrolled, and the baseline characteristics similar between the SAPT and MDI groups. Study completion is anticipated in June 2010. CONCLUSIONS: Results of this randomized controlled trial should help establish whether an integrated RT-CGM and CSII system benefits patients with type 1 diabetes more than MDI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE - To evaluate an algorithm guiding responses of continuous subcutaneous insulin infusion (CSII)-treated type 1 diabetic patients using real-time continuous glucose monitoring (RT-CGM). RESEARCH DESIGN AND METHODS - Sixty CSII-treated type 1 diabetic participants (aged 13-70 years, including adult and adolescent subgroups, with A1C =9.5%) were randomized in age-, sex-, and A1C-matched pairs. Phase 1 was an open 16-week multicenter randomized controlled trial. Group A was treated with CSII/RT-CGM with the algorithm, and group B was treated with CSII/RT-CGM without the algorithm. The primary outcome was the difference in time in target (4-10 mmol/l) glucose range on 6-day masked CGM. Secondary outcomes were differences in A1C, low (=3.9 mmol/l) glucose CGM time, and glycemic variability. Phase 2 was the week 16-32 follow-up. Group A was returned to usual care, and group B was provided with the algorithm. Glycemia parameters were as above. Comparisons were made between baseline and 16 weeks and 32 weeks. RESULTS - In phase 1, after withdrawals 29 of 30 subjects were left in group A and 28 of 30 subjects were left in group B. The change in target glucose time did not differ between groups. A1C fell (mean 7.9% [95% CI 7.7-8.2to 7.6% [7.2-8.0]; P <0.03) in group A but not in group B (7.8% [7.5-8.1] to 7.7 [7.3-8.0]; NS) with no difference between groups. More subjects in group A achieved A1C =7% than those in group B (2 of 29 to 14 of 29 vs. 4 of 28 to 7 of 28; P = 0.015). In phase 2, one participant was lost from each group. In group A, A1C returned to baseline with RT-CGM discontinuation but did not change in group B, who continued RT-CGM with addition of the algorithm. CONCLUSIONS - Early but not late algorithm provision to type 1 diabetic patients using CSII/RT-CGM did not increase the target glucose time but increased achievement of A1C =7%. Upon RT-CGM cessation, A1C returned to baseline. © 2010 by the American Diabetes Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Continuous subcutaneous insulin infusion (CSII) treatment among children with type 1 diabetes is increasing in Sweden. However, studies evaluating glycaemic control in children using CSII show inconsistent results. Omitting bolus insulin doses using CSII may cause reduced glycaemic control among adolescents. The distribution of responsibility for diabetes self-management between children and parents is often unclear and needs clarification. There is much published support for continued parental involvement and shared diabetes management during adolescence. Guided Self-Determination (GSD) is an empowerment-based, person-centred, reflection and problem solving method intended to guide the patient to become self-sufficient and develop life skills for managing difficulties in diabetes self-management. This method has been adapted for adolescents and parents as Guided Self-Determination-Young (GSD-Y). This study aims to evaluate the effect of an intervention with GSD-Y in groups of adolescents starting on insulin pumps and their parents on diabetes-related family conflicts, perceived health and quality of life (QoL), and metabolic control. Here, we describe the protocol and plans for study enrolment. Methods. This study is designed as a randomized, controlled, prospective, multicentre study. Eighty patients between 12-18 years of age who are planning to start CSII will be included. All adolescents and their parents will receive standard insulin pump training. The education intervention will be conducted when CSII is to be started and at four appointments in the first 4 months after starting CSII. The primary outcome is haemoglobin A1c levels. Secondary outcomes are perceived health and QoL, frequency of blood glucose self-monitoring and bolus doses, and usage of carbohydrate counting. The following instruments will be used to evaluate perceived health and QoL: Disabkids, 'Check your health', the Diabetes Family Conflict Scale and the Swedish Diabetes Empowerment Scale. Outcomes will be evaluated within and between groups by comparing data at baseline, and at 6 and 12 months after starting treatment. Results and discussion. In this study, we will assess the effect of starting an insulin pump together with the model of Guided Self-Determination to determine whether this approach leads to retention of improved glycaemic control, QoL, responsibility distribution and reduced diabetes-related conflicts in the family. Trial registration: Current controlled trials: ISRCTN22444034

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims at the development and evaluation of a personalized insulin infusion advisory system (IIAS), able to provide real-time estimations of the appropriate insulin infusion rate for type 1 diabetes mellitus (T1DM) patients using continuous glucose monitors and insulin pumps. The system is based on a nonlinear model-predictive controller (NMPC) that uses a personalized glucose-insulin metabolism model, consisting of two compartmental models and a recurrent neural network. The model takes as input patient's information regarding meal intake, glucose measurements, and insulin infusion rates, and provides glucose predictions. The predictions are fed to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. An algorithm based on fuzzy logic has been developed for the on-line adaptation of the NMPC control parameters. The IIAS has been in silico evaluated using an appropriate simulation environment (UVa T1DM simulator). The IIAS was able to handle various meal profiles, fasting conditions, interpatient variability, intraday variation in physiological parameters, and errors in meal amount estimations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Looking for a candidate substance inducing hepatobiliary dysfunction under parenteral nutrition (PN) in newborns, we recently discovered that newborn infusions extract large amounts of the plasticizer diethylhexylphthalate (DEHP) from commonly used polyvinylchloride (PVC) infusion lines. This plasticizer is well known to be genotoxic and teratogenic in animals and to cause changes in various organs and enzyme systems even in humans. The aim of this study was to examine the effect of DEHP, extracted in the same way and in the same amount as in newborns, on livers of young rabbits. Methods: Prepubertal rabbits received lipid emulsion through central IV lines continuously for 3 weeks either via PVC or polyethylene (PE) infusion systems. Livers were examined after 1 and 3 weeks by light and electron microscopy. Results: By light microscopy, hydropic degeneration, single-cell necrosis, fibrosis, and bile duct proliferation were observed more in the PVC group. Electron microscopy revealed multiple nuclear changes, clusters and atypical forms of peroxisomes, proliferation of smooth endoplasmic reticulum, increased deposition of lipofuscin, and a mild perisinusoidal fibrosis only in the PVC group. These changes, which are generally regarded as reaction upon a toxic stimulus, could be exclusively attributed to DEHP. Conclusions: This investigation proved that DEHP produces toxin-like changes in livers of young rabbits in the same dose, duration, and method of administration as in newborn infants. For this reason, it is likely that DEHP is the substance that causes hepatobiliary dysfunction in newborns under PN. Possible modes of action of DEHP are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare the diabetes-specific quality of life in subjects with type 1 diabetes treating their diabetes with multiple daily injections (MDI) to that of subjects on continuous subcutaneous insulin infusion (CSII).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: To assess the use of paediatric continuous subcutaneous infusion (CSII) under real-life conditions by analysing data recorded for up to 90 days and relating them to outcome. METHODS: Pump programming data from patients aged 0-18 years treated with CSII in 30 centres from 16 European countries and Israel were recorded during routine clinical visits. HbA(1c) was measured centrally. RESULTS: A total of 1,041 patients (age: 11.8 +/- 4.2 years; diabetes duration: 6.0 +/- 3.6 years; average CSII duration: 2.0 +/- 1.3 years; HbA(1c): 8.0 +/- 1.3% [means +/- SD]) participated. Glycaemic control was better in preschool (n = 142; 7.5 +/- 0.9%) and pre-adolescent (6-11 years, n = 321; 7.7 +/- 1.0%) children than in adolescent patients (12-18 years, n = 578; 8.3 +/- 1.4%). There was a significant negative correlation between HbA(1c) and daily bolus number, but not between HbA(1c) and total daily insulin dose. The use of <6.7 daily boluses was a significant predictor of an HbA(1c) level >7.5%. The incidence of severe hypoglycaemia and ketoacidosis was 6.63 and 6.26 events per 100 patient-years, respectively. CONCLUSIONS/INTERPRETATION: This large paediatric survey of CSII shows that glycaemic targets can be frequently achieved, particularly in young children, and the incidence of acute complications is low. Adequate substitution of basal and prandial insulin is associated with a better HbA(1c).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Continuous intraperitoneal insulin infusion (CIPII) with the DiaPort system using regular insulin was compared to continuous subcutaneous insulin infusion (CSII) using insulin Lispro, to investigate the frequency of hypoglycemia, blood glucose control, quality of life, and safety.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, an Insulin Infusion Advisory System (IIAS) for Type 1 diabetes patients, which use insulin pumps for the Continuous Subcutaneous Insulin Infusion (CSII) is presented. The purpose of the system is to estimate the appropriate insulin infusion rates. The system is based on a Non-Linear Model Predictive Controller (NMPC) which uses a hybrid model. The model comprises a Compartmental Model (CM), which simulates the absorption of the glucose to the blood due to meal intakes, and a Neural Network (NN), which simulates the glucose-insulin kinetics. The NN is a Recurrent NN (RNN) trained with the Real Time Recurrent Learning (RTRL) algorithm. The output of the model consists of short term glucose predictions and provides input to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. For the development and the evaluation of the IIAS, data generated from a Mathematical Model (MM) of a Type 1 diabetes patient have been used. The proposed control strategy is evaluated at multiple meal disturbances, various noise levels and additional time delays. The results indicate that the implemented IIAS is capable of handling multiple meals, which correspond to realistic meal profiles, large noise levels and time delays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An impaired glomerular filtration rate (GFR) leads to end-stage renal disease and increases the risks of cardiovascular disease and death. Persons with type 1 diabetes are at high risk for kidney disease, but there are no interventions that have been proved to prevent impairment of the GFR in this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microalbuminuria is a common diagnosis in the clinical care of patients with type 1 diabetes mellitus. Long-term outcomes after the development of microalbuminuria are variable.